Quantcast
Channel: RXSOL - Sewage Chemicals Treatment-40
Viewing all 2359 articles
Browse latest View live

Sodium Chlorite Flakes Powder

$
0
0

Sodiumchlorite Flakes or Powder 50% & 80% supplier in India and Middle East.

Alias: 

SODIUM CHLORITE; 7758-19-2; Chlorous acid, sodium salt; Textone; Chlorite sodium; sodiumchlorite

Active Matter: 
25
Application: 

Sodium Chlorite is being mainly supplied to textile industry, water purification Industry, etc. SODIUM CHLORITE pure  is a white crystalline solid. Difficult to burn, but accelerates the burning of organic substances. Forms explosive mixtures with certain combustible materials. Used in water purification, to bleach wood pulp, textile, fats, oils; and for many other uses.

Packing Size: 
50.00 Kg.(PWD)
Image: 
Thumb: 
Using Procedure: 

NaClO2 or ClNaO2 have 2 No of Hydrogen Bond Acceptor capacity. Most Commonly Used in water purification, to bleach wood pulp, textile, fats, oils; and for many other uses.

Note: 

Sodium chlorite is a powerful oxidizer which makes make it a useful pesticide and herbicide.  Sodium chlorite plays a very important role to deactivate many types of poisons by interacting with them and changing their chemical composition due to its powerful oxidizing powers. 

It is helpful in bleaching various types of materials, such as wood, oils, and other textile products.

Short Description: 
SodiumChlorite is also used for water treatment purpose.

Sodium Chlorite for DRINKING WATER : When put in an acid solution, sodium chlorite breaks down into chlorine dioxide. When added to a municipal water supply, chlorine dioxide helps control unwanted tastes and odors. It also aids in the removal of ions like iron and manganese. One added benefit is that it helps eliminate trihalomethanes in drinking water.

As a textile-bleaching agent, sodium chlorite is effective with various fibers. It can be used on cotton, bast fibers, and man-made fibers like nylon, Perlon, Dralon, and Rhovyl. It has an oxidizing effect on many of the natural waxes and pectins found in cellulose fibers. It helps solubilize them and makes the fiber more even and workable. It has the added benefit of destroying natural color matter without attacking the fibers themselves. This makes it useful for making permanent white fabrics without compromising tensile strength.

Sodium chlorite can be combined with citric acid for antimicrobial treatment. This treatment can be used on meats, poultry, fish, fruits and vegetables. It can be applied in food and water treatments to kill various microbial and parasites without eliminating healthy bacteria needed by our digestive system.

Sodium chlorite is also used for various industrial applications. It controls microbial contamination in industrial cooling systems and towers. It is used in place of chlorine in industrial ammonia plants because it does not react negatively with ammonia. Since it is an oxidizer, it is often a part of flue gas scrubber systems. Food-processing companies use it for washing fruits and vegetables because it is a fungicide. Meat and poultry are also washed with a solution, as is food processing equipment. Finally, it is an anti-mildew agent in detergent compositions and has been used in toothpaste and contact lens solutions.

Sodium chlorite applications.
As a disinfectant and purification chemical for water.
As a textile-bleaching and water anti-fouling agent. 
In the paper and electronics manufacturing industries as a bleaching agent.

Sodium Chlorite Flakes 50% & 80%.


Sewage Treatment Chlorination

$
0
0

Alkyl Dimethyl Benzyl Ammonium Chloride and ADBAC and Glutaraldehyde based treatment liquid.

Alias: 

ROCHEM S Treat, Chlorination of Seawage Treatment Plant

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Short Description: 
Sewage Treatment

We are ready to serve you with the Chemicals for Water treatment, like Polyelectrolyte, Sodium Meta Bi Sulphite, Ferric Chloride Anhydrous, Anionic Polyacrylamide PAM, Cationic Polyacrylamide PAM, Water Softening Chemical. 

Our Products that involves latest concepts, purest raw material & finest quality to achieve best filtration results in terms of efficiency & economy.

We also Supplying, Manufacturing & Trading in Effluent Treatment Chemicals, Sewage Treatment Plant Chemicals, R.O. Plant Chemicals, Swimming Pool Chemicals, DM Plant Chemicals, Activated Carbon all kind, Aluminum Chlorohydrate (ACH), Decolouring Agent and many more. At Innova Corporate (India),

We will be happy to assist you & share our expertise with you as & when Filtration is in demand.

Hydrogen Peroxide 6% Solution

$
0
0

Hydrogen peroxide (H2O2) is the only germicidal agent composed only of water and oxygen. Like ozone, it kills disease organisms by oxidation! For this reason, Hydrogen peroxide is considered the world’s safest all natural effective sanitizer.

Alias: 

Hydrogen Peroxide, Mild Disinfectan and cleaning agent

Active Matter: 
6%
Application: 

Application : Adults the elderly and children : Apply the solution directly with a PAD of cotton wool required.

Packing Size: 
500.00 Bottle Liq
Image: 
Thumb: 
Using Procedure: 

Active Ingredient : Hydrogen Peroxide 6%

Note: 

1. Cuts and infections

Soak any infections or cuts in 3% for five to ten minutes several times a day. Even gangrene that would not heal with any medicine has been healed by soaking in Hydrogen peroxide. Put half a bottle of hydrogen peroxide in your bath to help rid boils, fungus or other skin infections.

2. Rejuvenating Detoxifying Bath

Use about 2 quarts 3% Hydrogen peroxide to a tub of warm water. Soak at least 1/2 hour, adding hot water as needed to maintain a comfortable water temperature.

3. Foot Fungus

To cure a foot fungus, simply spray a 50/50 mixture of Hydrogen peroxide and water on them (especially the toes) every night and let dry.

4. Bird Mites Infections

Patients infected by tiny mites report that hydrogen peroxide effectively kills the mites on their skins. They spray it on their skin a couple of times (with a few minutes in between the applications) with amazing results.

5. Sinus Infections

A tablespoon of 3% Hydrogen peroxide added to 1 cup of non-chlorinated water can be used as a nasal spray. Depending on the degree of sinus involvement, one will have to adjust the amount of peroxide used.

6. Wound Care

3% H2O2 is used medically for cleaning wounds, removing dead tissue, and as an oral debriding agent. Peroxide stops slow (small vessel) wound bleeding/oozing, as well.

Some sources recommend soaking wounds for five to ten minutes several times a day. However, washing and rinsing action is sufficient. You shouldn’t leave the solution on open tissue for extended periods of time as, like many oxidative antiseptics, Hydrogen peroxide causes mild damage to tissue in open wounds. Therefore it is important to use with caution.

Personal Care

7. Mouthwash

Many people don’t realize that hydrogen peroxide makes a very effective and inexpensive mouthwash. Take one capful (the little white cap that comes with the bottle) and hold in your mouth for 10 minutes daily, then spit it out. You will not have canker sores and your teeth will be whiter. Use 3% H2O2 – add a dash of liquid chlorophyll for flavoring if desired.

8. Toothpaste

Use baking soda and add enough 3% H202 to make a paste.

9. Toothbrush

Or, just dip your brush in 3% H202 and brush. Soak your toothbrush in Hydrogen peroxide to keep them free of germs.

10. Tooth Ache

Hydrogen peroxide is not a pain killer; however, as an anti-viral, antibacterial and anti-fungal agent, it is effective at treating the pathogen that is causing the infection. The following is from my own personal experience: My dentist wanted to give me a root canal some time ago as one tooth was inflamed and, in her opinion, would die. I felt some discomfort but told her that I would give it chance to heal. I rinsed with hydrogen peroxide (several times a day) as well ascoconut oil (once a day). The discomfort went away and I have had no further problems with the tooth.

If you have a terrible toothache and cannot get to a dentist right away, put a capful of 3% Hydrogen peroxide into your mouth and hold it for 10 minutes several times a day. The pain will lessen greatly.

11. Tooth Whitening

Having used 3% Hydrogen peroxide as a mouth wash for sometime ago, I am thrilled to note that my teeth have been beautifully and effortlessly whitened. I used to pay so much for professional whitening, those silly strips and uncomfortable trays. Live and learn.

12. Douche

Add 2 capfuls of 3% Hydrogen peroxide in warm distilled water once to twice a week to remove even chronic yeast infections.

13. Colonic or Enema

For a colonic, add 1 cup (8 ozs.) 3% H202 to 5 gallons warm water. (Do not exceed this amount) For an enema, add 1 tablespoon of 3% H202 to a quart of warm distilled water.

14. Hair Lightening

Peroxide is a bleaching agent and is used for lightened hair. Dilute 3% Hydrogen peroxide with water (50 / 50) and spray the solution on your wet hair after a shower and comb it through. You will not have the peroxide burnt blonde hair like the hair dye packages, but more natural highlights if your hair is a light brown, faddish, or dirty blonde. It also lightens gradually so it’s not a drastic change.

15. Contact Lenses

Hydrogen peroxide is used as a disinfectant in CIBA Vision’s Clear Care no rub contact lens cleaning solution, due to its ability to break down the proteins that build up on the lense from the eye’s immune response, resulting in increased comfort for those with sensitive eyes.

Sanitizing / Disinfectant / Cleaning

16. In the Dishwasher

To disinfect your dishwasher, add 2 oz. of 3% Hydrogen peroxide to your regular washing formula.

17. Kitchen/Household surfaces

Clean your counters and table tops with hydrogen peroxide to kill germs and leave a fresh smell. Simply put a little on your dishrag when you wipe, or spray it on the counters.

Fill a spray bottle with a 50/50 mixture of 3% Hydrogen peroxide and water and keep it in every bathroom to disinfect without harming your septic system like bleach or most other disinfectants will. After rinsing off your wooden cutting board, pour or spray hydrogen peroxide (and then vinegar) on it to kill salmonella and other bacteria.

Keep a spray bottle of 3% (straight) to disinfect the interior of the refrigerator and kids’ school lunch boxes. You can also use hydrogen peroxide to clean glass and mirrors with no smearing. Use it in the bathroom to sanitize the counters, toilets, floors, etc.

Directions: It is best to use two spray bottles rather than mixing the solutions together. Put straight vinegar in one and straight Hydrogen peroxide in the other spray bottle. When you want to sanitize a surface (cutting board, counters, sink, cages, toys, toilets, floors, etc.) spray one mixture on the surface, then the other. When they mix, for a brief time the chemical action of the two make a very powerful sanitizer. You can rinse off the surface afterwards. This applies for kitchen surfaces as well as vegetable and food decontamination.

18. Humidifiers/Steamers

To clear the air, use 1 pint 3% hydrogen peroxide to 1 gallon of water in a humidifier or steamer.

19. Washing/Laundry

You can also add a cup of hydrogen peroxide instead of bleach to a load of whites in your laundry to whiten them. If there is blood on clothing, pour directly on the soiled spot. Let it sit for a minute, then rub it and rinse with cold water. Repeat if necessary.

Peroxide is a perfect alternate solution to keep those clothes white. Also, when chlorinating clothes, they tend to wear out faster – peroxide won’t do that.

20. Laundry / Stain Removing

3% Hydrogen peroxide is an effective stain remove if it is used fairly soon after a spill – although blood stains as old as 2 days have been successfully lifted with Hydrogen Peroxide. If a little peroxide is poured onto the stain it will bubble up in the area of the blood, due to a reaction with catalase. After a few minutes the excess liquid can be wiped up with a cloth or paper towel and the stain will be gone.

3% H2O2 must be applied to clothing before blood stains can be accidentally “set” with heated water. Cold water and soap are then used to remove the peroxide treated blood.

Please note: Hydrogen peroxide will bleach or discolor many fabrics.

Food Preparation

21. Food preparation/decontamination

Combination of vinegar and hydrogen peroxide make a cheap, effective and non-toxic disinfectant agent and is said to be more effective at killing pathogens than bleach. As it is non-toxic, you can use it to cleanse cooking and food preparation areas (as well as fruits and vegetables – see #24). In tests run at Virginia Polytechnic Institute and State University, pairing Vinegar and Hydrogen Peroxide mists, kills virtually all Salmonella, Shigella, or E. coli bacteria on heavily contaminated food and surfaces.

22. Vegetable Soak

Use as a vegetable wash or soak to kill bacteria and neutralize chemicals. Add 1/4 cup 3% H2O2 to a full sink of cold water. Soak light skinned (light lettuce) 20 minutes, thicker skinned (like cucumbers) 30 minutes. Drain, dry and refrigerate. Prolongs freshness.

If time is a problem, spray vegetables (and fruits) with a solution of 3%. Let stand for a few minutes, rinse and dry.

23. Meat Sanitizing

You can also use it to rinse off your meat before cooking.

24. Leftover tossed salad

To help keep leftover salads, spray with a solution of 1/2 cup water and 1 Tbsp. 5%. Drain, cover and refrigerate.

25. Marinade

Place meat, fish or poultry in a casserole (avoid using aluminium pans). Cover with a dilute solution of equal parts of water and 3% H202. Place loosely covered in refrigerator for 1/2 hour. Rinse and cook.

26. Sprouting Seeds

Add 1 ounce 3% Hydrogen peroxide to 1 pint of water and soak the seeds overnight. Add the same amount of hydrogen peroxide each time you rinse the seeds.

Grades of Hydrogen Peroxide

A) 3.5% Pharmaceutical Grade: This is the grade sold at your local drugstore or supermarket. This product is not recommended for internal use. It contains an assortment of stabilizers which shouldn’t be ingested. Various stabilizers include: acetanilide, phenol, sodium stanate and tertrasodium phosphate.

B) 6% Beautician Grade: This is used in beauty shops to color hair and is not recommended for internal use.

C) 30% Reagent Grade: This is used for various scientific experimentation and also contains stabilizers. It is also not for internal use.

D) 30% to 32% Electronic Grade: This is used to clean electronic parts and not for internal use.

E) 35% Technical Grade: This is a more concentrated product than the Reagent Grade and differs slightly in that phosphorus is added to help neutralize any chlorine from the water used to dilute it.

F) 35% Food Grade: This is used in the production of foods like cheese, eggs, and whey-containing products. It is also sprayed on the foil lining of aseptic packages containing fruit juices and milk products. THIS IS THE ONLY GRADE RECOMMENDED FOR INTERNAL USE.

G) 90%: This is used as an oxygen source for rocket fuel.

Short Description: 
Hydrogen peroxide is considered the world’s safest all natural effective sanitizer.

Hydrogen Peroxide 6% Solution supplier in Mumbai, Kandla, Visakhapatnam, Chennai, Kolkata, Fujairah, Dubai, Sharjah, Abu Dhabi.

Mild Disinfectan and cleaning agent

read more

Ammonium Persulfate (Pwd)

$
0
0

Alias: 

Ammonium Persulfate

Active Matter: 
99.2
Application: 

AMMONIUM PERSULFATE is a white crystalline solid. A strong oxidizing agent. Does not burn readily, but may cause spontaneous ignition of organic materials. Used as a bleaching agent and as a food preservative.

Ammonium persulfate is a standard ingredient in hair bleach

Packing Size: 
25.00 Kg.(PWD)
Image: 
Thumb: 
Using Procedure: 

The most important application for Ammonium Persulfate is in the water-based emulsion polymerisation of organic monomers in aqueous systems. The monomers are either sufficiently soluble in water and precipitate during polymerisation or polymerisation takes place in an aqueous emulsion of the monomers, as with styrene-butadiene and Acrylonitrile.

Other applications of Ammonium Persulphate (APS)

  • In the cosmetics industry as a booster for hair bleaches and an oxidizer in hair dyes
  • In the paper industry for re-pulping and de-inking
  • In order to recover metals and metal salts, for oxidative treatment of high grade metal ores
  • In the photographic industry for regenerating bleaching baths for color stock
  • For the production of desinfectants
  • In-situ decontamination of industrial areas: degradation of chlorinated hydrocarbons
  • In Oil Drilling
Note: 

Other Name : Ammonium persulfate

7727-54-0
Ammonium peroxydisulfate
Diammonium peroxydisulfate
Diammonium persulfate
Diammonium peroxodisulphate
Diammonium peroxydisulphate

Persulfate d'ammonium [French]

PEROXYDISULFURIC ACID, DIAMMONIUM SALT
EINECS 231-786-5
UN1444
Peroxydisulfuric acid (((HO)S(O)2)2O2), diammonium salt
diazanium sulfonatooxy sulfate
Persulfate d'ammonium
Ammoniumpersulfat
ammonium persuiphate
Ammoniumperoxodisulfat
Ammonium peroxodisulfate

Short Description: 
Ammonium Persulphate is a strong oxidising agent

Ammonium Persulfate is a white, crystalline, odourless salt consisting of technically pure ammonium peroxydisulfate with selected particle size distribution and silicic acid to enhance the free-flowing properties.  Ammonium Persulfate has also been utilized to study protein-protein interactions via photoinitiated crosslinking chemistry. Other applications of Ammonium Persulfate include its use as a reducer and retarder in photography, the manufacture of aniline dyes, electroplating, the decolorizing and deodorizing of oils. A protocol on the APS-mediated modification of polypropylene membranes with polyaniline has been published. Ammonium Persulfate has been used to prepare biodegradable macroporous hydrogels for application as cross-linkable biomaterials. 

read more

Barium Chloride Solution, 10% Neutralized

$
0
0

RXSOL brand highly purified and well balanced Barium Chloride 10% solution chemically plays role during Sulfate Test, to pricipitate as Barium Sulfate crystal of uniform size. 

Other Higher Concentration Product ::: Barium Chloride saturated Solution

Alias: 

Barium Chloride Solution

Application: 

Water Testing Procedures Manual ( Full Range Lab testing   Methods with standard  composition ratio Of Reagents  ::: Available with us  at 2700 INR or 54 US$ or 207 AED

Packing Size: 
1.00 Bottle Liq
Image: 
Thumb: 
Using Procedure: 

Apparatus Required :::  Filter photometer complete with assorted laboratory glassware. 

Chemicals Required

Glycerol Sulfate Solution
Barium Chloride (Natural )  Solution
Sulfate Standard

Procedure of Test

This procedure uses a wavelength of 420 nm and a cell with a light path of approximately 10-mm. First prepare a calibration curve for the photometer using successive dilutions of the sulfate standard to adequately cover the range of sulfate in the samples to be tested.  The dilutions of the standard should be treated in exactly the same manner as that shown below for analysis of the water samples.  Using a 50-ml plastic graduate, add 50 ml of sample to a 125-ml glass flask. Pipet 10 ml of glycerol sulfate solution into the flask and swirl the solution. Pipet 5 ml of distilled water into the flask, swirl the solution and use this solution to set the photometer at zero absorbance. Discard the solution and rinse the flask with distilled water. Into a second 50-ml sample, pipet 10 ml of glycerol sulfate solution and swirl. Adjust the temperature of the sample to 70 to 75F, and pipet 5 ml of neutral barium chloride solution into the same flask. Stir the solution by rotating a rubber paddle between the palms at moderate speed for exactly five seconds. Wait exactly five minutes, and then measure the absorbance on the photometer. 

Calculation of Results  The sulfate concentration in parts per million as SO4  is obtained by reference to the prepared sulfate calibration curve. 

Limitations of Test 

Color or large amounts of suspended matter will interfere with this method,  but some suspended matter may be removed by filtration. Also the presence of color and suspended matter is compensated for to some extent by the blank determination. Silica in excess of 500 ppm will interfere, and in samples containing large amounts of organic material, it may not be possible to precipitate barium sulfate satisfactorily.  

Short Description: 
RXSOL brand highly purified and well balanced Barium Chloride 10% solution chemically plays role during Sulfate Test, to pricipitate as Barium Sulfate crystal of uniform size.

Sulfite test solution

read more

ALKALINITY Titration Method for Boiler & Cooling Water

$
0
0

ALKALINITY Titration Method for Boiler & Cooling Water ( TITRIMETRIC METHOD 0-200 PPM )

The presence of alkalinity in a water sample may be due to many different substances.  However, for the sake of simplicity, the presence of bicarbonate, carbonate, and hydroxide ions is commonly considered as alkalinity.  The points of change in colour of phenolphthalein and methyl orange indicators, which occur at pH 8.3 and pH 4.3 provide standard reference points which are almost universally used to express alkalinity.

Application: 

Alkalinity Titrimetric Method (0-200 ppm) 

Principle Theory

This test is based on the determination of alkalinity by titration with standard acid to the phenolphthalein color change (or to a pH of 8.3) and to the methyl orange color change (or a pH of 4.3).  For determination of hydroxide alkalinity only, barium chloride is added prior to titration to precipitate the carbonate ions.  Titration is then taken only to the phenolphthalein end point.  A pH meter may be used instead of the indicators to determine the end points of the titration.

Apparatus Required

Buret 25 ml - 1
Porcelain Cup, 210 ml    -  1
Glass stirring rod      -  1
Graduate,  50 ml - 1
Pipet, delivery, 5 ml      -  1
(1 pH meter- optional)      

 

Chemicals Required

Barium Chloride, 10%
Hydrochloric Acid, 0.02N
Methyl Orange Indicator
Methyl Purple Indicator
Phenolphthalein Indicator
Sulfuric Acid, 0.02N. 

QUICK HANDY ON SITE TEST can be obtaine through   our EASY to USE METHOD ::: RXSOL-62-5515-001 

Packing Size: 
1.00 Complete SET
Image: 
Thumb: 
Using Procedure: 

Testing Procedure

Phenolphthalein (P) and Methyl Orange (M) Alkalinity.

Measure 50 ml of sample into a graduated cylinder and transfer to the casserole.  Add four or five drops of phenolphthalein indicator.  If P alkalinity is present, the sample will turn red.  Add standard 0.02N sulfuric acid from the buret, drop by drop, until the last trace of red color is removed by a single drop.  Record volume of titrant added as the P alkalinity reading. 

Add four drops of methyl orange indicator (if no red color developed on the addition of the phenolphthalein indicator, proceed directly to this point) Continue adding acid dropwise until a change in color from yellow to salmon pink occurs.  Record the total volume (including titrant added for the P reading) as the M alkalinity.  In some cases where the methyl orange color change may be difficult to detect, methyl purple indicator may be used in place of the methyl orange.  The methyl purple color change is from green to gray to purple, with the endpoint being the first change to a definite purple. 

In place of indicators, a pH meter may be used for the titration.  The P alkalinity reading is taken to be the volume of titrant required to bring the solution to a pH 8.3 while the M reading is taken as the volume required to bring the pH to 4.3.  The pH meter should be calibrated prior to use according to manufacturers instructions.  The buffers used for standardization should be within the 4.3 to 8.3 pH range. 

Hydroxide Alkalinity 

Measure 50 ml of sample into  the  graduated  cylinder and transfer to the casserole.  Using the pipet, add 5 ml of barium chloride and stir vigorously.  Add four to five drops of phenolphthalein indicator and stir.  If the sample does not turn red, hydroxide alkalinity is not present.  If the sample turns red, add 0.02N hydrochloric acid dropwise until the color changes from red to colorless.  Record the volume of titrant delivered.

Results Calculation FORMULA :::   

ppm alkalinity (as CaCO3) =   ml 0.02N sulfuric acid         x     1000  /    ml sample 

(for hydroxide alkalinity substitute ml 0.02N hydrochloric acid for ml 0.02N sulfuric acid) Using a 50 ml sample, the alkalinity becomes ml of acid titrant multiplied by 20. 

Note: 

Limitations of Test

Phenolphthalein (P) and Methyl Orange (M) Alkalinity

The alkalinity measured from the titration to phenolphthalein end point or P alkalinity is considered to be equivalent to the sum of all the hydroxide ion present plus one half of the carbonate ion present.  The total alkalinity by titration to the methyl orange endpoint or M alkalinity includes the other half of the carbonate ion plus any bicarbonate that was originally present.  The presence of phosphate, silica, organic or other buffers may affect the titration and the calculation of the form of alkalinity present may be in error.    

The presence of bases other than hydroxide, carbon and bicarbonate will interfere directly.
Common bases titratable by acids include sulfide (S=  ) , hydrosulfide ( HS- ), cyanide ( CN-)  and ammonia (NH3) . All these will add to the apparent concentration of one or more of the alkalinities .

measured.  Care should be exercised in interpreting alkalinities found in these water strictly in terms of scaling tendency.  However, under normal circumstances in plant control, expression of result only as the P and M alkalinity actually determined is satisfactory and is preferred from the standpoint of simplicity. 

Hydroxide Alkalinity

The method for hydroxide alkalinity is considered accurate only to within 10 per cent.  High silica, organic matter and aluminates can interfere with the determination, as will the bases mentioned above.  High sulfate content in the sample can produce turbidity which may mask the endpoint.  However, the method for hydroxide alkalinity is satisfactory for routine control and can be valuable in the control of lime-soda softening. 

Short Description: 
Lab Testing method not suitable for on site testing, But this method is more accurate and scientifc

read more

One Shot Universal Liquitreat 100 25 Ltrs

$
0
0

It is a well - balanced blend for boiler water treatment products, resulting in a scale and corrosion control by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.

Alias: 

Liquitreat, Nalfleet® BWT LIQUID PLUS, Care Treat 3 Boiler 2, Drew Ameroid, Arboiler WT, BWT 104P ( Nor chem ), B.W.T. NEW FORMULA (EQUAL TO DREW - AGK 100), DM-511, EAZY BWT-1, ONE SHOT BWT

Active Matter: 
54-60
Application: 

The dosage rate is dependent on bioler operating condition, feed 2-3 ltrs of RXSOL-50-5001-025 solution for per thousand ltr of bioler water then control the system by periodic Alkalinity test procedure. If p-Alkalinity is below 200 ppm increase the ratio of RXSOL BWT 5001 solution. If p-Alkalinity is above 400 ppm reduce the concentration of RXSOL-50-5001-025 solution by dilution with water. RXSOL-50-5001-025 is strongly alkaline.RXSOL-50-5001-025  is best applied heat or diluted with any convenient strength on a continuous basis using a suitable chemicals pump. The product should be applied to the boiler feed tank or feed line to ensure adequate mixing.
 

CHARACTERISTIC :

  • Convenient liquid treatment, which provides the basic alkalinity on which successful water treatment depends.
  • Provides optimum conditions for hardness control to function.
  • Neutralizes acid conditions.
  • Will assist in keeping silica in suspension.
  • Simple test to determine level of treatment.
  • Can be used in boilers of all pressures.
  • Can be used as a neutralizer after acid cleaning operations
  • Suitable for use with all auxiliary boilers; waste heat units; economizers, package boilers, smoke and water tube boilers.
  • Dispersant action suspends sludge and sediment particles for efficient blow down.
  • Oxygen scavenging for optimum protection.
  • Protects boiler, steam lines, condensate lines and feed water lines from corrosion.
  • Fast action due to catalyst.
  • Simple test to determine level of treatment.
Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

Control is by simple  boiler water tests or RX CLEANSERS  can provide a suitable test  kits for this purpose.

Used in low pressure and auxillary boilers

:::::::::::::::::::::Alkalinity  TEST FOR BOILER & COOLING WATER ::::::::::::::::::::::::

REAGENT & APPARATUS :
Reagent:  RXSOL TK 7 , TK 8 , TK 9 , . Apparatus : TEST TUBE , Titrator or DROPPER

PROCEDURE for p-ALKALINITY  test ( STEP WISE ):

  1. Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK7 and mix with the stirring rod , If  sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) .
  3. Add RXSOL TK9  drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 25 ppm of p-Alkalinity , expressed as CaCO3

RESULT  : Each DROPS is equivalent to  25 PPM of Alkalinity .

NOTE :    p-Alkalinity VALUE  =  25 X ( Total Number of DROPS of TK9 , during 3rdstep  )

        

PROCEDURE for p-ALKALINITY  & TOTAL ALKALINITY ( STEP WISE ):

  1. Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK7 and mix with the stirring rod , If  sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) then proceed to STEP- 4.
  3. Add RXSOL TK9  drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 15 ppm of p-Alkalinity , expressed as CaCO3
  4. Add 2-3 drops of RXSOL TK8 and mix with stirring rod , the sample will turn to BLUISH-GREEN .
  5. AddRXSOL TK9 carefully by counting drop by drop and mixing throughly until a light reddish  pink  colour develop.

RESULT  : Each DROPS is equivalent to 25 PPM of Alkalinity .

NOTE :    p-Alkalinity ppm CaCO3VALUE ( A )  =  25 X ( Total Number of DROPS of TK9 , during 3rdstep  )

Total Alkalinity ppm CaCO3VALUE  =  A +  { 25 X ( Total Number of DROPS of TK9 , during 5th step  )}

 

 

 

NUMBER OF DROPS OF TK9                                                                                     p-Alkalinity as CaCO3                                

                        1 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>25
                        2 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>50

                        3 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 75
                        4 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  100

                        5 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 125
                       10 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  250

                       20 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  500
                       30>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>750

                       40 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  1000
 

Optimum Result    :   p-Alkalinity  level  is between 100 to  150 PPM is suggested.

 if  p-Alkalinity level is more then 150 ppm then level should be reduced by increased BLOW DOWN process with immediate effect.   

For Below  50 ppm  , Dose ½ Ltrs of RXSOL-50-5001-025 for 1000 Ltrs of  BOILER WATER , to maintain p-Alkalinity level 100 ppm.

Refill pack : REPLACEMENTS  

TK7   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

TK8   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

TK9   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

Note: 

Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

 

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce CO2 in steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Short Description: 
It is a well - balanced blend for boiler water treatment products, resulting in a scale and corrosion control by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressur

Chemical feed should be continuous. Chemical pumping rates can create problems especially for neat feed set ups. Using on/off feed systems such as a recycle timer can create problems. Chemical feed pumps should be sized or product strengths should be adjusted to allow continuous feed.

Steam and carbon dioxide leave continuously, so setting up a neutralizing amine pump to feed intermittently can lead to wide variations in condensate pH control. If sampling is done from a condensate receiver, the tank volume may buffer the variations and the changes may not be noticed, but corrosion could be occurring to areas of the piping that see the rapidly changing pH.

If polymeric dispersants, phosphonates, phosphate, or chelants are fed intermittently into the feedwater using a recycle timer, and the amines are not fed continuously, a cycle of iron slugs returning in the condensate can be followed by slugs of high dispersancy cleaning of the iron from the deaerator and dragging it into the boiler.

Load changes can affect chemical concentrations when the chemical feed is base fed. Example: Steam production of one million lbs./day; 4% blowdown; 20% active boiler polymer product fed at 5 pounds per day. The calculated daily average polymer concentration would be 24 ppm. Assume peak plant production load is 60,000 lbs./hr., but during the overnight hours the load is only 5,000 lbs./hr. If the dispersant is being fed continuously over the 24 hours, during the 8- hour low load period, the boiler polymer concentration would have increased to over 200 ppm. Upon high fire when production resumes, carryover is very possible because of over concentrating the polymeric dispersant.

Chemical feed needs to be paced to steam production, especially where significant load changes occur.

Carbon dioxide can concentrate in steam and condensate making neutralizing amine treatment impractical. Carbon dioxide levels can be relatively low in steam exiting a boiler at only a few ppm, but if there are areas where it becomes “trapped” and can accumulate, concentrations can reach extremely high levels into the hundreds or even thousands of ppm.

CO2 is a non-condensable gas. It has a distribution ratio in the steam piping and condenses at points throughout the system. At the boiling point, the solubility of the gas in water is extremely low. The solubility of the CO2 is actually lower in the condensate than it is in the steam. For the CO2 to escape from the steam into the water it will accumulate in the steam space just above the water level until the partial pressure becomes high enough for the CO2 in the incoming steam to be able to exit into the condensate. This creates a steady state condition of CO2 coming in and exiting, but an area of severe localized corrosion occurs where the carbon dioxide concentration is high.

The highest CO2 concentration normally occurs just above the condensate water level. If there is an area where condensation is occurring and running down pipes or the sides of vessels, the CO2 concentration will be very high and the pH will be about 5.3 – 5.5 in that location creating high corrosion rates.

The solubility of CO2 increases dramatically as the condensate temperature falls below 212 °F. When there is an accumulation of CO2 in an area and the condensate temperature is relatively low, the amount of carbon dioxide going into solution will be extremely high. Where low-pressure steam is used that contains CO2 and the heat exchange process has relatively close temperature differentials between the steam and the condensate, there is potential for high uptake of the CO2 into the condensate and localized low pH.

Neutralizing amines are selected in an effort to condense in the right concentrations to carbon dioxide condensation levels throughout the steam system. Neutralizing amines cannot control corrosion where this localized accumulation of carbon dioxide occurs since the high CO2 overwhelms the demand for the amine. Even point source addition of amine may not be able to satisfy the demand.

Where the concentrating effect of CO2 occurs, methods of reducing the problem include eliminating or minimizing CO2 in the steam, venting off the CO2 in the localized area, eliminating condensate in the area, applying a filming amine or metal passivator, or using higher temperature steam and increasing condensate temperature to reduce the CO2 content in the condensate.

read more

BIOCIDE MICRO Cooling Water 20 Ltr

$
0
0

Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system.

it is a strong algae depressant fully compatible with alkalizing and flocculating agents normally used in cooling / boiler water.  Algae growth is the main cause of colour in water.  Routine and weekly additions of RXSOL-40-4009-020 establish a buffer action to control very rapid algae growth. 

Alias: 

GREEN MICROBIOCIDE, MICROORGANISM CONTROL, NALCO ST40-BIOCIDE

Packing Size: 
20.00 Ltr.
Image: 
Thumb: 
Short Description: 
Strong algae depressant fully compatible with alkalizing and flocculating agents normally used in cooling / boiler water. Algae growth is the main cause of colour in water. Routine and weekly additions of RXSOL-40-4009-020 establish a buffer action to control very rapid algae growth.

Microbiocide for cooling water Bacteria and Algae Control.


Algae Control

$
0
0

Developed for controlling the growth of algae, bacteria, and fungi in recirculating water systems such as cooling towers, evaporative condensers, closed cooling water systems and industrial air-washing systems.

Alias: 

Totaline P902-3501, AQUACIDE 2360

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Short Description: 
Developed for controlling the growth of algae, bacteria, and fungi in recirculating water systems such as cooling towers, evaporative condensers, closed cooling water systems and industrial air-washing systems.

Rocor NB Liquid With Indicator 25 Ltr

$
0
0

Alias: 

DEWT NC, Liquid EWT, Cooltreat, Jacket Water Inhibitor, nalco 2000 , Engine water treatment, NCLT diesel ,LIQUIGAURD 2000, ENGINE JACKET WATER CONDITIONER , Gyrocor W.C., Aquafine 103, Care Treat

Active Matter: 
68 - 75
Application: 

Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4034-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves cooling efficiency by maintaining clean heat transfer surfaces , from Radiators, DG - sets, Closed Cooling and chiller System.

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

Refer to technical datasheet.

GENERAL RECOMMENDATION

Nitrite (as PPM NO2) 100-200 300-600 700-900 1100-1300   
RXSOL-40-4033-025 / 1000L 13.0  11.3 8-10 5-7   1.5-3.5

NOTE ::: --   If nitrite level becomes 1440-2400 then doses should be ZERO.

Note: 

Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in  water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.

Short Description: 
Corrosion Inhibitor for Water Systems having unique formulation with highly concentrated liquid cooling treatment compound
Information: 

 Ship chandlers in Mumbai, Kandla, Chennai - Ennore, Kolkata - Haldia,  Vizag - Visakhapatnam, Dubai - Sharjah. 

DIESEL WT, Rocor NB Liquid, CWT Diesel QC2, Liquidewt. Free Nitrite Test Kit available on purchase of more then 500 Ltr Rocor NB Liquid. Our higher concentration of ragent resulting low dosage of chemicals to obtain highe Nitrite label in cooling water system. And compare our Price of ROCOR NB in India - Middle East  before closing your deal, we are sure to provide you BEST price among all. 

Rocor NB MSDS and using procedure, E catalogue available online. ROCOR NB liquid classified as corrosion inhibitor for cooling water system of diesel engines, compressors, process cooling systems etc.

Rocor NB Liquid is used in a dosage of 1200 - 3000 mg/l nitrite (NO2), dependent on the chloride level. ROCOR NB Liquid is the ideal corrosion inhibitor for closed heating or cooling systems, such as diesel engine.  Rocor NB Liquid is nitrite/borate based compound with additional water softner.

 

Rocor NB Liquid is a liquid, nitrite/borate based compound with organic ... Use the dosage chart overleaf to adjust treatment to obtain the optimum level.

Rocor Nb liquid supplier and stockist in Mumbai, Nhava seva, Kandla - Gandhidham, Chennai - Ennore, Vizag - Visakhapatnam, Gangavaram, Kolkata - Haldia, Paradip, Fujairah - Dubai,  Middle East - Gulf. If your cooling system is small dont waste your money to buy BIG VOLUME of container, mail us to buy small container like 5 Ltr of Rocor NB as it is easy to handle and control extra wastage during storge. Corrosion Inhibitor for cooling water system protect against corrosion and scale formation.

Effective corrosion inhibitor for the common ferrous and non-ferrous metals found in engine cooling water systems. Diesel engine cooling water systems. Popular in Shipping and Marine oilfied Industries as a major component in cooling water system.

read more

ALUMINIUM SULFATE

$
0
0

Its wide range of usage is in water treatment, because it can act as an coagulant, flocculant, precipitant and emulsion breaker. As coagulant and flocculant, aluminum sulfate successfully removes turbidity, suspended solids and colloidal color,reduces biochemical oxygen demand (BOD) and extremely clarifies potable, process and wastewaters.

 

Alias: 

ALUM

Application: 

Also used as foam fire extinguisher 

Aluminium sulfate reacts with sodium bicarbonate to which foam stabilizer has been added, producing carbon dioxide for fire extinguishing foam. 

 

 

 

  • Al2(SO4)3 + 6 NaHCO3 → 3 Na2SO4 + 2 Al(OH)3 + 6 CO2
  • The carbon dioxide is trapped by the foam stabilizer and creates a thick foam which will float on top of hydrocarbon fuels and seal off access to atmospheric oxygen, smothering the fire. Chemical foam was unsuitable for use on polar solvents such as alcohol, as the fuel would mix with and break down the foam blanket. The carbon dioxide generated also served to propel the foam out of the container, be it a portable fire extinguisher or fixed installation using hoselines. Chemical foam is considered obsolete in the United States and has been replaced by synthetic mechanical foams, such as AFFF which have a longer shelf life, are more effective, and more versatile, although some countries such as Japan and India continue to use it.

     

     

    In the construction industry, it is used as waterproofing agent and accelerator in concrete.

    Packing Size: 
    20.00 Slab Kg
    Image: 
    Thumb: 
    Using Procedure: 

    - For the production of Aluminum salts, Soaps and Aluminum Hydroxide Gel. - As a Catalyst in Ethane Production.
    - Textile industry.
    - Paper production. 

    - For the production of Glycerin
    - As a Foaming Agent in Fiber Foams.
    - As a Clearing Agent for Fats and Foams. - In sugar industry. 

    Note: 

    properties :::---

     

  • 1. Properties: Including anhydrous and hydrous(18 crystal water) type. Usually, the crystal separated out from aqueous solution at the normal temperature is A12(SO4) 3.18H2O; When weathering, the average molecular structure is A12(SO4) 3.14H2O, may appear white powdery, with bright flake or crystalline flakelet, odorless, to change the taste from sweetness to slight astringency.

    2. Uses: Solidifying agent ( to purify grease and water ) and stabilizer in pasteurization of albumin ( including: liquid or refrigerated whole egg, egg white or egg yolk ), the maximum allowable use level ( FAO/WHO.1984 ) is 0.036%.

    3. Standard: HG2225-2001

    4. State: Flake or powder

    5. Packing: 25/50 kg/bag, 25MT/20'FCL

  •  

     

     

     

     

     

     

     

     

     

     

     

     

    Short Description: 
    it can act as an coagulant, flocculant, precipitant and emulsion breaker. As coagulant and flocculant, aluminum sulfate successfully removes turbidity, suspended solids and colloidal color,reduces biochemical oxygen demand (BOD) and extremely clarifies po
    Information: 

     Aluminium Sulfate is one of popular water treatment chemicals. We are one of popular high purity Alum - Fitkarin manufacturer, Supplier and exporter in India. We are keeping ready stock of materials in our Mumbai, Gandhidham, Surat, Kolkata, Chennai - Ennore, Visakhapatnam, Fujairah - Dubai

    ALUMINUM SULFATE, Aluminium sulfate, Dialuminum trisulfate, 10043-01-3, Aluminum sulfate (2:3), Filter Alum, Aluminum sulphate, Aluminium sulphate, Dialuminum sulfate, Papermaker's Alum Sulfuric acid, aluminum salt (3:2), Aluminum alum, Pickle Alum, Pearl Alum, Dialuminum sulphate

    Cake alum (VAN), Aluminum sesquisulfate, Aluminum alum (VAN), Hi Soft C 2, Aluminum(III) silfate, Caswell No. 031A, Nalco 7530, Tai-Ace S 100

    Tai-Ace S 150, Aluminum sulfate anhydrous, Aluminum sulfate (3:2), Sulfuric acid, aluminum salt, Sulphuric acid, aluminium salt, CCRIS 9170, UNII-I7T908772F, alum, aluminum hydrogen sulfate, aluminum potassium sulfate, aluminum sulfate, potassium aluminum sulfate

    Aluminum Alum;. Aluminum sulfate anhydrous; Aluminum trisulfate anhydrous; Cake Alum; Dialuminum sulfate; Sulfuric acid aluminum salt (3:2); Aluminiumsulfat (German); Sulfato de aluminio (Spanish); Sulfate d'aluminium (French); Aluminum sesquisulfate

    Aluminum sulfate is a water-soluble white crystalline solid compound with the chemical formula Al2(SO4)3. Aluminium Sulfate is a coagulating agent in the purification of drinking water and wastewater treatment plants,  pH regulation of garden soil, and other commercial or industrial applications like paper manufacturing, in firefighting foams, and in sewage treatment and water purification.

    Aluminum Sulfate Anhydrous is an aluminium salt adsorbs and precipitates protein antigens in solution.It is primarily used as a coagulating agent in minor cuts and abrasions.

    Aluminium sulfate, Al2(SO4)3, is widely used by wastewater treatment plant as a flocculating agent and in the drinking water for purification. And in industry, Its most common applications are in the pulp and paper industry.

    How Aluminium Sulfate works as a water purifier and discolouring agent?

    Aluminium sulfate has highly charged cation of Al3+ which is powerfully attracting Negative particles from any solution such as those which discolour our raw water supplies, are attracted to this cation, react with it and then precipitate out of solution as ionic solids.

    Mumbai, Kandla, Chennai Ennore, Visakhapatnam, Kolkata, Fujairah - Dubai

    Aluminium Sulfate is used as coagulant to remove almost any kind of impurities in water. Its main function is to provide electrically charged ions capable to neutralize effectively the electric charges of the colloid material present in the water, thus allowing them to come together. The alum reacts rapidly with the water alkalinities. This produces a gelatinous precipitate of aluminum hydroxide that entraps and absorbs impurities.

    Alum - Fitkari Slab

    Hydrazine Hydrate 25 Kg

    $
    0
    0

    No oxygen is entering the boiler with the feed water when hydrazine is present in the water ( This will help to decrease oxygen on HP, LP boiler )
     

    Active Matter: 
    100
    Application: 

    Hydrazine is used as an oxygen scavenger for high pressure boilers in power plants and other industries to reduce corrosion of metal pipes and fittings. The test for hydrazine can be controlled by http://rxmarine.com/hydrazine-test-kit in which several solutions have been formulated into a single, stable reagent. The method is both sensitive and easy to perform. It is used mostly for the determination of small amounts of hydrazine in boiler feedwater. There are no common interferences.

    The establishment of protective metal oxide layers through the use of reducing agents (such as hydrazine, hydroquinone, and other oxygen scavengers) is known as metal passivation or metal conditioning. Although "metal passivation" refers to the direct reaction of the compound with the metal oxide and "metal conditioning" more broadly refers to the promotion of a protective surface, the two terms are frequently used interchangeably.

    The reaction of hydrazine and hydroquinone, which leads to the passivation of iron-based metals, proceeds according to the following reactions:

    N2H4 6Fe2O3® 4Fe3O4 2H2O  N2
    hydrazine   hematite   magnetite   water   nitrogen

     

    C6H4(OH)2 + 3Fe2O3® 2Fe3O4 + C6H4O2 + H2O
    hydroquinone  hematite  magnetite  benzoquinone  water

     

    Similar reactions occur with copper-based metals:

    N2H4 + 4CuO® 2Cu2O + 2H2O + N2
    hydrazine  cupric oxide  cuprous oxide  water  nitrogen

     

    C6H6O2 + 2CuO® Cu2O + C6H4O2 + H2O
    hydroquinone  cupric oxide  cuprous oxide  benzoquinone  water

     

    Magnetite and cuprous oxide form protective films on the metal surface. Because these oxides are formed under reducing conditions, removal of the dissolved oxygen from boiler feedwater and condensate promotes their formation. The effective application of oxygen scavengers indirectly leads to passivated metal surfaces and less metal oxide transport to the boiler whether or not the scavenger reacts directly with the metal surface.

    A significant reduction in feedwater oxygen and metal oxides can occur with proper application of oxygen scavengers.

    Packing Size: 
    25.00 Ltr.
    Image: 
    Thumb: 
    Using Procedure: 

    The establishment of protective metal oxide lay-ers through the use of reducing agents (such as hydrazine, hydroquinone, and other oxygen scavengers) is known as metal passivation or metal conditioning. Although "metal passivation" refers to the direct reaction of the compound with the metal oxide and "metal conditioning" more broadly refers to the promotion of a protective surface, the two terms are frequently used interchangeably.

    The reaction of hydrazine and hydroquinone, which leads to the passivation of iron-based metals, proceeds according to the following reactions:

    N2H4 6Fe2O3® 4Fe3O4 2H2O  N2
    hydrazine   hematite   magnetite   water   nitrogen

     

    C6H4(OH)2 + 3Fe2O3® 2Fe3O4 + C6H4O2 + H2O
    hydroquinone  hematite  magnetite  benzoquinone  water

     

    Similar reactions occur with copper-based metals:

    N2H4 + 4CuO® 2Cu2O + 2H2O + N2
    hydrazine  cupric oxide  cuprous oxide  water  nitrogen

     

    C6H6O2 + 2CuO® Cu2O + C6H4O2 + H2O
    hydroquinone  cupric oxide  cuprous oxide  benzoquinone  water

     

    Magnetite and cuprous oxide form protective films on the metal surface. Because these oxides are formed under reducing conditions, removal of the dissolved oxygen from boiler feedwater and condensate promotes their formation. The effective application of oxygen scavengers indirectly leads to passivated metal surfaces and less metal oxide transport to the boiler whether or not the scavenger reacts directly with the metal surface.

    A significant reduction in feedwater oxygen and metal oxides can occur with proper application of oxygen scavengers.

    Note: 

    Why control balance of Hydrazine must required ?
    Control of Hydarazine level in Boiler water is very important.  As proper level maintenance protect metal machinery parts from corrosion, However, precautions must be taken to prevent excess dose of hydrazine chemical as excess hydrazine will begin to decompose at temperature above 200oC to form Ammonia.

    Hydrazine is one of popular an alternative Oxygen Scavenger. It is very important to protect boiler components from feed boiler water corrosion. 

    Test Procedure ::: rxmarine.com/hydrazine-test-kit

    Safety Accessories: 
    Short Description: 
    No oxygen is entering the boiler with the feed water when hydrazine is present in the water ( This will help to decrease oxygen on HP, LP boiler )

    Hydazine Dose Level

    Thumb rule for Hydarzine dose is, Low pressure boiler required high dose of Hydrazine ( 0.1 to 0.2 ppm level of hydrazine ) While for High pressure boiler low dose of hydrazine required (0.05 to 0.1ppm value)

     

    Recommended dose of Hydrazine :

    Low Pressure Boiler ( 0 to 40 bar )

    0.10 to 0.2  ppm level  

    Medium Pressure Boiler ( 41 to 60 bar )

     0.1 to 0.15 ppm level  

    High Pressure Boiler ( more then 60 bar) 

    0.05 to 0.10 ppm level

    Valuable Boiler Water Treatment Chemicals :

    Hydrazine Hydrate (50 ~ 51% as N2H4) plays very important role for corrosion protection in boilers.

    Activated Hydrazine (34 ~ 35% as N2H4) Catalyzed Hydrazine solution for corrosion Protection and related equipment.

    Morpholine (C4H9NO). Technical Grade for Boiler Water Treatment. Purity Not less than 99%.

    Acid Inhibitor : For the suppression of Hydrochloric Acid attack on Ferrous alloys, Cuprous alloys and Titanium alloys, effec up to 94°C with efficiency not less than 75% in 5% HCI solution and Acid Inhibitor concentration 2%.

    Ammonia 25% (NH4OH).
    25% as ammonium Hydroxide used high pressure Boiler water treatment.
    It is a clear colorless liquid.
    PH 11-12 @ 20 °C.
    Density 0.9 g/cm3.
    Chloride (CL) 0.002 mg/liter maximum.
    Iron (Fe) 0.002 mg/liter maximum.

    Hardness Stabilizer :
    Polyacrylate material of low molecular weight.
    Non-volatile used for scale inhibition in sea water treatment.
    The product is miscible with water in all proportions. And is clear Liquid.
    PH valve 5-7.
    Density @ 20°C Approx. 40%.
    Chemical Characterization Sodium Polyacrylate, Modified, Aqueous solution.
    Solidification temperature -20°C.
    Flash point >100°C.
    Ignition temperature >200°C.

    Hydrazine Hydrate supplier in Mumbai, Kolkata, Gandhidham, Chennai, Visakhapatnam, Fujairah, Dubai, Sharjah. Hydrazine Hydrate plays very important role for corrosion protection in boilers water treatment. 

    Oxygen scavenger for high pressure boilers

    read more

    pH Booster Morpholine Base

    $
    0
    0

    RXSOL pH Boosters are liquid  alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.

    Active Matter: 
    60 - 63
    Application: 

    RXSOL-40-5024-020 have antiscalant property which will help to formation of scale inside the boiler. This makes it profitable for users by savings of power and labor, and increase in production.  As Uses of antiscalants is a prime necessity to meet up with production targets.

    pH booster is an alkaline liquid formulation designed to increase alkalinity of  feed water  of boiler. It is also used to reduce corrosion of feed water tank,lines & pump.  

    CORROSION REDUCTION

    pH booster Increases ph of the feed water reducing corrosiveness.it also increases alkalinity in boiler water reducing scaling & corrosion of the boiler metal.

    EASY SLUDGE REMOVAL

    pH booster is helps in formation of non adherent sludge.it fluidises the sludge which is then removed easily during normal blow-down. non- toxic and non-corrosive liquid formulation and therefore can be handled  easily.

    Packing Size: 
    25.00 Ltr.
    Image: 
    Thumb: 
    Using Procedure: 

    RXSOL  pH Boosters are dosed depending upon the feed water characteristic and alkalinity requirement. It is compatible with all other treatment chemicals. It is dosed exactly as per the dosage rate and method of RXSOL-50-5001-025

     

    EASY TO HANDLE

    pH booster is non- toxic liquid formulation and therefore can be handled  easily. pH booster should be dosed continuously. Dose the dilute solution  in boiler feed  water line.  

    Note: 

    Key Features & Benefits:-

    Minimizes corrosion of feed water tank, lines and pump

    Imparts water and sludge conditioning to minimize scaling and deposition

    Compatible with other treatment Chmicals

    Completely biodegradable chemicals
    Its antiscale property helps and Prevent from Scaling

    Minimum downtime required for descaling
    Multipurpose,therefore easy to use
    Proper maintenance of boiler saves Power / Fuel saving upto 70%. Formation of Scale is major issue and contol of scale makes Effectively heat transfer which Increase productivity.

    Short Description: 
    RXSOL pH Boosters are morpholine based alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.

    Hydrazine Hydrate (50 ~ 51% as N2H4);

    50 ~ 51% as N2H4 solution, Chloride less than 0.1% as NaCL, For corrosion protection in boilers.

    Activated Hydrazine (34 ~ 35% as N2H4).
    34 ~ 35% as N2H4, Chloride less than 0.1% as NaCl, Catalyzed Hydrazine solution for corrosion Pr and related equipment.

    Morpholine (C4H9NO).
    Technical Grade for Boiler Water Treatment. Purity Not less than 99%.

    Acid Inhibitor.
    For the suppression of Hydrochloric Acid attack on Ferrous alloys, Cuprous alloys and Titanium alloys, effec up to 94°C with efficiency not less than 75% in 5% HCI solution and Acid Inhibitor concentration 2%.

    Ammonia 25% (NH4OH).
    25% as ammonium Hydroxide used high pressure Boiler water treatment.
    It is a clear colorless liquid.
    PH 11-12 @ 20 °C.
    Density 0.9 g/cm3.
    Chloride (CL) 0.002 mg/liter maximum.
    Iron (Fe) 0.002 mg/liter maximum.

    Hardness Stabilizer (POC 3000) :
    Polyacrylate material of low molecular weight.
    Non-volatile used for scale inhibition in sea water treatment.
    The product is miscible with water in all proportions. And is clear Liquid.
    PH valve 5-7.
    Density @ 20°C Approx. 40%.
    Chemical Characterization Sodium Polyacrylate, Modified, Aqueous solution.
    Solidification temperature -20°C.
    Flash point >100°C.
    Ignition temperature >200°C.

    read more

    GLUTARALDEHYDE

    $
    0
    0

    Glutaraldehyde supplier and exporter. Glutaraldehyde is a disinfectant and medication. As a disinfectant it is used to sterilize surgical instruments and other areas.

    Application: 

    Intermediate used in the production of:
    • Photographic chemicals
    • Crop protection
    • Pharmaceuticals
    • Corrosion inhibitors

     PRODUCT NAME    : GLUTARALDEHYDE (SOL)
     CAS number      : 111-30-8
     UN number      : 
     Formula    : OHC(CH2)3CHO
     Odour      : ROTTEN APPLE LIKE
     Solubility in water       : COMPLETE
     Density         : 1.124 AT 20 oc
     Boiling point  : 188oc
     Melting point    : -10oc
     Viscosity     : 
     Flashpoint    : 
     Explosive limits    : 
     Vapour pressure     : 1 mbar at 20oc
     Skin absorption/irritation          : YES
     TLV       Country  NL             Year  1995   : ppm                 0.25 Cmg/m3
     Pollution category    1994   : D
    Packing Size: 
    230.00 Kg.(Liq)
    Image: 
    Thumb: 
    Using Procedure: 

    Glutaraldehyde is a colorless, oily, liquid-chemical with a pungent odor. Glutaraldehyde also used in water treatment. Industrial water uses of glutaraldehyde include treatment of cooling water, wastewater, process water systems.

    Note: 

    Storage and Handling :

    Glutaraldehyde storage original containers and kept below 25ºC. Ensure thorough ventilation of stores and work areas. Avoid aerosol formation and keep under inert gas.

    Safety :

    Glutaraldehyde  is irritating and can be toxic to skin, eyes and respiratory system. Will cause burns and sensitization by inhalation and skin contact.

    Short Description: 
    Used for water treatment. Industrial water uses of glutaraldehyde include treatment of cooling water, wastewater, process water systems.

    Glutaraldehyde
    CAS No.111-30-8

    Packing220kgs/drum and also available in 1.1MT/IBC drum,
    Usage  ::: Glutraldehyde can be used as bactericide, disinfectant, cross-linker for protein, leather tanning agent... etc.

    As a reliable supplier in Mumbai, Chennai, Kolkata, Gandhidham, Fujairah, Dubai, Abudhabi, Sharjah.

    Aqua Break RX 20 Ltr

    $
    0
    0

    Acts as superior quality cleaner/degreaser. It is a new technology surfactant degreaser ( high solvency and emulsification effect ) , Being free from caustic and hydrocarbons it is very gentle on hands & ideal for cleaning walls, wood works, metal and other areas for removal of grease, oil, sludge, carbon deposits, general dirt and grime.
     

    Alias: 

    Aqua Sol, Aquabreak PX

    Active Matter: 
    63-72
    Application: 

    Can be used for all types of cleaning and degreasing including engine rooms and cargo tanks. Can be used as accoomodation cleaner for Bulkheads, Deck, Toilet etc. Suitable for cleaning of Soiled Textiles such as rugs, cover, mats etc. Effectively Clean Fibre Glass, Boats, Hulls and Painted Surfaces.

    NOTE : Bio-degradable product, it is low toxic, non-caustic and from hydrocarbons.                       

    Fields:-
    RXSOL-16-3003-020 containing  corrosion  inhibitors to  prevents the  corrosion of metals such as Aluminium, Copper, Brass and Tin. RXSOL-16-3003-020 is designed to clean Animal / Vegetables oils, Fats, Hydrocarbon removes Dirt, Iink, Carbonized grease, Oil, Heavy oils etc. Specialized for all types of cleaning and degreasing.may be applied by brush, handspray or used in ultrasonic cleaning tanks, immersion soak tanks and high and low pressure spray appliances. May be used neat or diluted by up to 50 parts of water according to the amount and type of soil to be removed.

    Tank Cleaning:-
    (Cargo tank cleaning after mineral, animal, vegetable and fish oil. )                                               

    Packing Size: 
    20.00 Ltr.
    Image: 
    Thumb: 
    Using Procedure: 

    1st of all by stripping suction removes all possible oil (greasy materials). To prevents evaporation of lighter fraction oil flush the system with cold water.May be brushed on, sprayed (Hand spray/Direct injection) recirculate  the system with RXSOL-16-3003-020 Solution

    1.

    Cleaning with   washing machines. Dose rate: 0.3-5 ltr per ton wash water (0.03-0.5%).     

    2.

    Cleaning with recirculation method. Dose rate: 0.5-10 ltr per ton wash water, (0.05-1%).      

    3.

    Spot cleaning. Hand sprayed neat or diluted up to 1-10  parts water and left for about 15-20 minutes before.washing.off.    

    DOSAGE:-

    Nature Of Residue

    Hand Spray

    Direct Injection

    Circulation

    Veg.Oil (Drying/Non Drying Fish Oil,Alcohol,Acids,Amines)

    1-10%

    0.03-0.5%

    0.05-0.7 %

    ORGANIC MATERIAL (HYDROCARBON)

    NA

    0.0 5-0.5%

    0.05-0.7%

    RXSOL-16-3003-020 has numerous general cleaning applications including the removal of greases, oil, sludge, carbon deposits, general dirt and grime. Can be used as engine room cleaner. Suitable for cargo tank cleaning. Can be used as accommodation cleaner for bulkheads, decks, toilets. Suitable for cleaning of soiled textiles as rugs, covers, mats, overalls, etc. Effectively cleans glass fibre boats, hulls and painted surfaces

    Note: 

    WHY RXSOL-16-3003-020 is better ?

    An economical  highly concentrated product.

    Compatible with oily water separators.

    Releasing the oil phase for reclamation.

    Suitable for all types of floors. Deodorizing nature.

    Eliminates the need to buy & stock duplicate products because of its effectiveness.

    Also used for gas and hydrocarbon freeing of tanks. Free from caustic & hydrcarbon, Non flammable Water based, Biodegradable. Safe to metal

     

    Short Description: 
    Concentrated cleaning agent based on nonionic detergents, alkaline components, special components to stabilise the hardness and corrosion inhibitors for aluminium.
    Information: 

     Aqubreak is classified as one of versatile cleaner which is free from caustic and solvent. Good Blend of surfactant makes easy OIL EMULSIFYING properties. Easily availabe at all Indian and Middle East port. 

    Degreasing Agent, Non Caustic Cleaner, aquabreak px msds, marine universal cleaner

    aquatuff

    enviroclean

    PX, Aquabreak, Cleaning Agent, Water Based Degreaser

    Ship galleys decks cleaning agent. Best Oil cleaning action in Engine room, Helpfull for cargo tank cleaning. Also can be utilized as multipurpose cleaning agent for soiled textiles as rugs, covers, mats, overalls etc. Also effectively cleans boats, machinery parts, fibreglass area.

    Aquabreak available in various packing  size for making smooth supply in Mumbai, JNPT, GOA, Manglore, Kandla - Gandhidham, Chennai - Ennore, Vizag _ Viakhapatnam, Gangavaram, Kakinada, Kolkata, Haldia, Middle East, Dubai, Fujairah, Sharjah

    Best classified cleaner for Shiping Industries, Oil and Rigs, Railway, Petroleum Industries. Multi-purpose utility of Aqua Break Eliminates the need to buy & stock duplicate products because of its effectiveness.

    Also refer this link :::
     

    Aqua Break RX 20 Ltr - Concentrated cleaning agent based on nonionic detergents, alkaline components, special components to stabilise the hardness and corrosion inhibitors for aluminium.RXSOL-16-3003-020

    Aqua Break RX 25 Ltrs - New technology surfactant degreaser for removal of grease, oil, sludge, carbon deposits, general dirt and grime. designed to clean Animal / Vegetables oils, Fats, Hydrocarbon removes Dirt, Iink, Carbonized grease, Oil, Heavy oils etc.RXSOL-16-3003-025

    Aqua Break RX 210 Ltrs  -  Specialized for all types of cleaning and degreasing. Effective to clean Animal / Vegetable oils, Fats, Hydrocarbon removes Dirt, Iink, Carbonized grease, Oil, Heavy oils etc. Effectively Clean Fibre Glass, Boats, Hulls and Painted Surfaces.RXSOL-16-3003-210

    Aqua Break RX HD 20 Ltr - Numerous general cleaning applications including the remover of grease, oil, sludge, carbon deposits, general dirt and grimeRXSOL-20-3017-020

    Aqua Break RX HD 25 Ltr  - Advanced degreaser for engine rooms and cargo tanks it can be used for all types of cleaning and degreasing including engine rooms and cargo tanks. Can be used as an accommodation cleaner for bulkheads, deck, toilet etc. Suitable for cleaning of soiled textiles such as rugs, cover, mats etc. EffectivelyRXSOL-20-3017-025

    Aqua Break RX HD 210 Ltr - Cargo tank cleaning after mineral, animal, vegetable and fish oil, Effective grease cleaner and free from caustic and hydrocarbonsRXSOL-20-3017-210

    Degreaser cum oil water separator

    read more


    Sodium Hypo Chlorite

    $
    0
    0

    A 12% solution is widely used in waterworks for the chlorination of water and a 15% solution is more commonly used for disinfection of waste water in treatment plants. High-test hypochlorite (HTH) is sold for chlorination of swimming pools and contains approximately 30% calcium hypochlorite. The crystalline salt is also sold for the same use; this salt usually contains less than 50% of calcium hypochlorite. However, the level of active chlorine may be much higher.

    Alias: 

    Chloros , Bleach , Fungicide and an oxidizing bleach / Sodium Hypo Chlorite (12-15%)

    Active Matter: 
    <p> 12 - 15%</p>
    Application: 
    • Also used as a disinfectant and germicide , especially in the sterilization of water.

    • It is also used for making wool unshrinkable and in the manufactire of chloroform.

    • For the purpose of disinfection and bleaching  , a weak soln. ( 1.2 % ) is used. For purifying water 0.02 to 0 .2 % volumetric is sufficientPotable Water Treatment

    • Aquatics and Pools

    • Odor Control/Corrosion Control

    • Food & Beverage Processing

    • Wastewater Treatment

    • Cooling Towers, Inland Power Stations & Industry

    • Irrigation Systems

    • Agriculture/Farming

    Packing Size: 
    60.00 Kg.(Liq)
    Image: 
    Thumb: 
    Using Procedure: 

    A weak soln. ( 1.2 % ) is used. For purifying water
    0.02 to 0 .2 % volumetric is sufficient for Potable Water Treatment

    General formulation to calculate  how much bleach is needed to add to a tank or a pipeline to disinfect it to a given chlorine residual using a given disinfectant. Usually someone wants to know how to meet an AWWA Standard (like C651-92, Disinfection of Water Mains). The equation below should be used to estimate the amount of sodium / Calcium hypochlorite (Chlorine Water is 6.00% sodium hypochlorite) needed to disinfect a given quantity of water to a desired chlorine concentration. 

                                                                            req'd residual in ppm
      Valume of hypo  =  volume of water  x  (  ----------------------------- )
                                                                               1,000,000 x hypo %

    For example , say you had installed a new 5,000 gallon tank and wanted to make sure that you had at least a 100 ppm solution of chlorine in it.

    How much 6.00% Hypochlorite would you need to add  ?

    • (5,000 gal x 100 ppm) / (1,000,000 x .06) = 8.33 gallons

    How much 12% Hypochlorite solution would you need ?

    • (5,000 gal x 100 ppm) / (1,000,000 x .12) = 4.17 gallons

    If you use calcium hypochlorite (the white, powder version of chlorine, like HTH pool cleaner), the equation becomes:

                                                                                                                  req'd residual in PPM
    Wgt. of Calcium Hypo (lbs)= gal of water x 8.33 lb / gal m x   ( ----------------------------- )
                                                                                                                   1,000,000 x hypo %

    • This is simply the previous equation multiplied by the conversion factor of 8.33 pounds per gallon of water.

    Let's assume that we still need to disinfect 5,000 gallons at 100 ppm.

    How many pounds of 65% calcium hypochlorite (HTH pool cleaner) are needed?

    • (8.33 lbs/ gal. x 5,000 gal x 100 ppm) / (1,000,000 x .65) = 6.4 pounds
    Note: 

    Note : Store in cool place
     

    UN No :  1791
    IMDG CLASS : 8

    PACKING GROUP : III

    ODOUR  : IRRITATING , PUNGENT ODOUR

    R31: Contact with acids liberates toxic gases

    R34: Causes burns

    S-PHRASES

    S1/2: Keep locked up and out of the reach of children.

    S28: After contact with skin, wash immediately with plenty of water

    S45: In case of accident or if you feel unwell, seek  medical advice (show the label where possible)

    S50: Do not mix with acids

    S50: Do not mix with reducing agents

    X2: Restricted to professional users.Warning! Avoid exposure - obtain special instructions before use.

    EMERGENCY AND FIRST AID PROCEDURES

    EYE:

    OBJECT IS TO FLUSH MATERIAL OUR IMMEDIATELY AND THEN SEEK MEDICAL ATTENTION IMMEDIATELY flush eyes with a directed stream of water at least 15 minutes while forcibly holding eye lids apart to ensure complete irrigation of all eye and lid tissue. Washing eyes within one (1) minute is essential to achieve maximum effectiveness. SEEK MEDICAL ATTENTION IMMEDIATELY.

    SKIN:

    SEEK MEDICAL ATTENTION IMMEDIAELY. Flush thoroughly with cold water under shower while removing contaminated clothing and shoes. CONTINUE TO FLUSH UNTIL MEDICAL ATTENTION ARRIVES. Discard non-rubber shoes. Wash clothing before reuse.

    INIIALATION:

    Remove to fresh air. If breathing is difficult, have trained person administer oxygen. If respiration stops, give mouth-to-mouth resuscitation. GET MEDICAL ATTENTION IMMEDIATELY.

    INGESTION:

               NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. If swallowed, DO NOT INDUCE VOMITING. Give large quantities of milk or gelatin solution. If these are not available give large quantities of water. If vomiting occurs spontaneously, keep airway clear and give more milk, gelatin solution or water, GET MEDICAL ATTENTION IMMEDIATELY. Avoid vomiting, lavages or acidic antidotes. NOTE TO PHYSICIAN: Sodium Hypochlorite is an alkaline corrosive. For exposure by ingestion do not use emesis, lavages or acidic antidotes. Dilute immediately by giving milk, melted ice cream, beaten egg white, starch paste or antacids such as milk magnesia. Aluminum hydroxide gel or magnesium trisilicate gel. Avoid sodium bicarbonate because of  carbon di-oxide release. Sodium thiosulphate solution may prove beneficial by reducing unreacted material

     

    Other Related PRODUCTS LINKS :

    Textile Hypo Bleach , SODIUM HYPO CHLORITE , Sod Hypo Chlorite conc activeCHLORINE , CHLORINE LIQUID , Calcium Hypo Chlorite Conc active Chlorine , Chlorine Tablet cyanurate , Chlorine Tablets Calcium Based , DYE REMOVER ORG DICHLOR , Dechlorination Soln De-Hypo

    Short Description: 
    Waterworks for the chlorination of water
    Information: 

    Sodium Hypo chlorite Bleach manufactred by RX MARINE INTERNATIONAL is highly concentrate toward saturated chlorine value. We are well known sodium hypochlorite manufacturer and supplier in India and Middle East. Our products are bsed on electro chemical process where sodium works as cation and a hypochlorite in the form of anion.

    Sodium Hypochlorite, Bleach sodium hypochlorite uses, sodium hypochlorite ph value plays very important role during chlorination. sodium hypochlorite formulation chemically defined as sodium cation and a hypochlorite anion.Sodium hypochlorite also popular as disinfectant cleaner. 

    Sodium hypochlorite msds is available through above link, Otherwise kindly share your request through our email id rxmarine@gmail.com

    We are keeping ready stock of Sodium Hypochlorite NaOCl for sale in India and Middle East.  We are not only providing Sodium Hypochlorite Solution, but also having complete solution for Ship marine Industries. We are keeping full range of Deck/Engine/Cabin Stores Chemicals Hold cleaning chemicals, Tank Cleaner Detergent, Boiler and cooling water treatment chemicals. Among Ship Chandlers in India's and UAE we are most popular name to supply all kinds of Marine chemicals. We covers and stock all chemicals at Kandla, Mundra, Sikka, Hazira, Mumbai (Bombay), Jnpt, Pipavav, Manglore, Chennai - Ennore, Vizag - Visakhapatnam, Gangavaram, Kakinada, Kolkata - Haldia - Paradip, Fujairah, Sharjah, Dubai Abu Dhabi.

    We are popular among shipchandler and our other exhisting customer as a quality product Manufacturer of Sodium Hypo Chlorite, Suppliers of Sodium Hypo Chlorite, Dealers of Sodium Hypo Chlorite in India and UAE. 

    NaClO

    Hydrogen Peroxide

    $
    0
    0

    Hydrogen peroxide is a chemical compound with the formula H2O2. It is the simplest peroxide (a compound with an oxygen-oxygen single bond) and in its pure form is a colorless liquid, slightly more viscous than water.

    Application: 

    Hydrogen Peroxide has many use including House Hold, Domestic. Agriculture, Textile , Industries , Medical and West water Treatment.

    Packing Size: 
    25.00 Ltr.
    Image: 
    Thumb: 
    Using Procedure: 

    House Hold : One of the most common uses of hydrogen peroxide is as a disinfectant. Spray it on surfaces like kitchen counter top and wipe with a clean rag. It can be used as a mouthwash too. You have to dilute the chemical with water and use it for rinsing the mouth. This mouthwash is also said to whiten teeth. Ensure that you do not swallow the liquid, while rinsing.
    It can also be used to wash vegetables and fruits, in order to get rid of germs and pesticides. Add some hydrogen peroxide to a bowl full of water (you may also add a few pinches of salt). Soak the veggies and fruits for some time. Remove them and rinse with cold water, before use.This chemical is also used to purify water in swimming pools.
     

    Agriculture : Farmers use it as an insecticide. They spray diluted form of this chemical, on plants, so that the pests and weeds get killed, without causing harm to the plants. Its also used for watering plants. Mix an ounce of this chemical with a quart of water and use it on plants. Apart from boosting the level of oxygen in the soil, this mixture is also said to prevent root rot. Some people soak seeds in it, after diluting it with water. It is said that this will fasten the process of germination. For this purpose have to mix 1.5 teaspoons of hydrogen peroxide in a cup of water.

    Textile: It acts as a stain remover. Put 1 spoon tea in 1 bucket water  and let it sit for a while. After that, rinse the stains with water and soap.
    As it has bleaching property, it is used as a bleach too.

    IIndustrial :

    Reduced Sulfur Compound Treatment for Refinery Wastewater

    Sulfur compounds, such as hydrogen sulfide, thiosulfates and mercaptans, can present serious refinery wastewater problems. Hydrogen peroxide treatment is a cost effective way to treat these reduced sulfur species.

    Supplemental Dissolved Oxygen to Reduce BOD and COD

    Hydrogen peroxide has been used to reduce BOD and COD in refinery wastewater Supply of Supplemental Dissolved Oxygen (DO) when biological treatment systems experience temporary overloads or equipment failure.Predigestion of wastewater which contains moderate to high levels of compounds that are toxic, inhibitory or recalcitrant to biological treatment.As indicated by these examples, hydrogen peroxide can be used as a stand-alone treatment or as an enhancement to existing physical or biological treatment processes, depending on the situation.

    Wastewater Pretreatment
    Hydrogen peroxide is one of the most versatile, dependable and environmentally compatible oxidizing agents. The relative safety and simplicity of its use as an oxidizing agent has led to the development of a number of applications in refinery wastewater systems.

     

    Note: 

    Product specification

    Molar mass :::--- 34.0147 g/mol
    Appearance :::--- light blue; colorless in solution
    Odor :::--- sharpBoiling point :::--- 150.2 °C, 423 K, 302 °F
    Solubility in water :::---Miscible
    Solubility :::--- soluble in ether, alcohol insoluble in petroleum ether
    Viscosity :::---1.245 cP (20 °C)

    Short Description: 
    Pure form is a colorless liquid, slightly more viscous than water.

    Hydrogen Perxoide supplier and exporter in India and Middle East. H2O2 used as an oxidizer, bleaching agent and antiseptic.

    H2O2

    Borax Detergent Booster

    $
    0
    0

    Borax Detergent Booster laudary cleaning agent. Pure Sodium Tetraborate Decahydrate 99.9% manufacturer and supplier.

    Alias: 

    Sodium Tetraborate Decahydrate

    Active Matter: 
    99
    Application: 

    Increasing whitenes: Borax converts some of the water molecules to hydrogen peroxide, which is a whitening agent. Borax enhances the action of bleach, whether you add it separately or it is present in your laundry detergent.

     

    Softens hard water: Borax has a high pH, a measure of the acidity and alkalinity of water. It softens water to a pH of about 8. A neutral pH is 7. Borax is a buffering agent, which keeps the water at the best pH for cleaning action.

    Removes soap residue from your clothing: The borates in Borax work to keep soap dispersed throughout the load, so it is more likely to rinse out.
     

    Neutralizes laundry odors: Borax inhibits fungi, which often grow in the moist environment of your washing machine and can give it a musty odor. It also helps get rid of ammonia odor in baby fabrics, diapers, bed pads and incontinence pads. Borax can also inhibit enzymes that produce body odor that can cling to workout clothing and the underarm areas of shirts.

    Disinfects clothing: Borax inhibits many organisms, including fungi.

    Packing Size: 
    1.00 Kg.(PWD)
    Image: 
    Thumb: 
    Using Procedure: 

    Increases the stain-removal ability of your detergent: Pre-soak your laundry for 30 minutes in a solution of a tablespoon of borax per gallon of warm water or a 1/2 cup of borax in the washer in a pre-soak cycle. The alkaline pH of borax helps break down acidic stains, such as tomato or mustard. It works on grease and oil stains as well.

    It is safe to mix with chlorine bleach and detergents, and it enhances their actions.

    Note: 

    Borax also can be use such as pest control, be sure you are not leaving quantities around that could be eaten by children or pets.

    Short Description: 
    Detergent Booster laundary whitening agent

    Borax Detergent Booster is Stain removal product.

    Borax Detergent Booster supplier in Mumbai, Kandla, Kolkata, Chennai, Visakhapatnam, Fujairah, Dubai, Sharjah.

    Stain Remover in Detergent

    Hydrogen Sulfide Scavenger 210 Ltr

    $
    0
    0

    Hydrogen Sulfide Scavenger -RXSOL-11-5014-210  corrosive and Acidic GAS Remover

    H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure

    Alias: 

    MC MX 2-1106 , H2S Scavenger Trizene based

    Active Matter: 
    98-100
    Application: 

    Hydrogen sulfide (H2S) naturally occurs and may already by present information can be the result of sulphate reducing bacteria (SRB) in your process systems. Ones established, it can potentially be carried in hydrocarbon streams, resulting in servere gatharing lines, creating high failure rates in your production.

    Through strategic H2S scavenger applications and speciality chemicals, RX Marine International chemicals experts can help reduce H2S levels and lower overall solids in your system, reducing any gas or fluid souring while controlling corrosion.

    If you encounter hydrogen sulfide in your system, RX Marine International can perform a fluid compatibility test to determine H2S levels and customize a chemical solution to fit your production needs.

    Packing Size: 
    220.00 Ltr.
    Image: 
    Thumb: 
    Using Procedure: 

    Hydrogen Sulfide Scavenger is works as a corrosive Acidic GAS Remover from system as well as from working station. which is not only damaging precious instrument but also creating Worker Health  problem by attacking on respiratory system.

    The neutralizing effect of H2S is the result of a simple chemical reaction between the components of an RXSOL-11-5014-210 molecule and an offensive, toxic odour molecule. 

           Hydrogen Sulfide (H2S) + RXSOL-11-5014-210  =  Bi Sulfide salt
           
    The resultant products in the above equations are safe and stabilized compounds, which are neutral, harmless, and odour free. They dissolve in water and will not be re-released into the atmosphere in normal conditions.

    Note: 

    Benefits:

    • Improved safety due to reduced H2S content
    • Meet contract sales limit for H2S content
    • Removal of hydrogen sulfide gas from process systems, therefore reducing corrosion
    • The reaction products can be easily removed from the process systems
    • Maintains asset integrity and reduces the need for new equipment
    Short Description: 
    Removal of hydrogen sulfide gas from process systems, therefore reducing corrosion

    HYDROGEN SULFIDE SCAVANGER

    MMA Triazine is a cyclic tertiary triamine. It is mainly used as a scavenger for sour gases like H2S and mercaptans in gaseous or liquid hydrocarbon streams

    The MMA-triazine reacts with H2S or mercaptan resulting in the formation of dithiazines. Both MMA-triazine and its reaction products are readily biodegradable.

    MMA-triazine is available as an aqueous solution with concentration up to 42%.

    KEY Feature
    • Can be applied in both aqueous and hydrocarbon streams
    • Effective removal of H2S down to ppm levels
    • Product and its reaction products are readily biodegradable

    TYPICAL PROPERTIES
    Appearance   Clear, colorless liquid
    Autoignition Temperature   190°C
    Boiling Point    100% solution149°C
    Density    42% solution; at 25°C1.02 g/cm3
    Flash Point    Closed Cup88°C
    Freezing Point  42% solution <-50°C
    Freezing Point100% solution <-27°C

    Octanol-water partition coefficient, log Pow   0.76
    Vapor Pressure    @ 20°C2.79-3.4 hPa
    Viscosity  @ 20°C 13 mPa·s
    Viscosity @ 40°C  5.1 mPa·s

    Water solubility : Soluble

    H2S Scavenger Trizene based

    read more

    Diesel Guard NB Pwd ( Rust Scale Inhibitor ) DEWT

    $
    0
    0

    RXSOL-40-4002-025  is a dry powder, nitrite / borate based compound with unique formulation with organic corrosion inhibitors and anti-scalants for use in closed cooling water systems.

    A non-chromate powdered product incorporated with corrosion inhibitors specially designed to inhibit and prevent corrosion in diesel cooling waters systems.

    Alias: 

    Rust Scale Inhibitor, Engine water treatment / NITRITE BORATE BASED CORROSION INHIBITOR, DCWT, Chemical INDION 5547, KURILEX L - 109

    Active Matter: 
    78 - 83%
    Application: 

    Prevents corrosion and scale formation in closed cooling water systems of internal combustion engines, compressors, diesel generators. Used as a cooling water additive for ships’ diesel engines.

    Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings

    for a period of time.



    If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.



    Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide

    Packing Size: 
    25.00 Kg.(PWD)
    Image: 
    Thumb: 
    Using Procedure: 

    Method Of Use:-Properly   clean  the  system  with  water  and  alkaline  liquid ,  if  necessary. Add  0 .05-0.2 %  of  RXSOL-40-4002-025  in system or recommended Nitrite level1400 – 2500 ppm can be measured and controlled  by  any standard  RXSOL test  kit  for  Nitrite, Chloride  test  also helps  to detect excess  contamination  to  maintain  accepted  levels. when the product is dosed as recommended  limit By buffering action of   RXSOL-40-4002-025   , pHshould be maintained between 8.3 and 10 by the treatment.

    Note:-Initial dosage for an untreated system is 2 Kg of RXSOL-40-4002-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite.  For  best  result  and  prolonged  engine  life  add  RXSOL-40-4002-025 every  500 -6500  km. or  250  to  300 hours  of  running  time  or  every  2 month   interval. 

    Note: 

    Diesel Guard NB Pwd (RXSOL-40-4002-025) COOLING WATER TREAT CORROSION INHIBITOR ( HIGH  NITRITE CONTENT)  RXSOL-40-4002-025 Powder (For Radiators, DG - sets, Closed Cooling System)

    Safety Accessories: 
    Short Description: 
    Dry powder, nitrite / borate based compound with unique formulation with organic corrosion inhibitors and anti-scalants for use in closed cooling water systems.

    The stable oxide film that is formed by RXSOL-40-4002-025 prevents corrosion caused by electrolytic action between dissimilar   metals used in the system . RXSOL-40-4002-025 has been field tested and found to have no detrimental effects on non metallic substances such as seals, glands, packing, hoses, gaskets etc., normally used in these’systems

    Application-DG*Sets:-Internal combustion engines closed circuit cooling system compressor cooling system. RXSOL-40-4002-025 incorporates superior corrosion inhibitors to prevent corrosion works by free of scale deposits.

    RXSOL-40-4002-025  is a  dry powder, nitrite/borate based compound with unique formulation with organic Corrosion Inhibitors , Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is also acts as a corrosion inhibitor ( Protects all the metals including cast iron , mild steel , copper.

    Corrosion Inhibitor Powder for Cooling System

    Viewing all 2359 articles