RXSOL pH Boosters are liquid alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.
RXSOL-40-5024-020 have antiscalant property which will help to formation of scale inside the boiler. This makes it profitable for users by savings of power and labor, and increase in production. As Uses of antiscalants is a prime necessity to meet up with production targets.
pH booster is an alkaline liquid formulation designed to increase alkalinity of feed water of boiler. It is also used to reduce corrosion of feed water tank,lines & pump.
CORROSION REDUCTION
pH booster Increases ph of the feed water reducing corrosiveness.it also increases alkalinity in boiler water reducing scaling & corrosion of the boiler metal.
EASY SLUDGE REMOVAL
pH booster is helps in formation of non adherent sludge.it fluidises the sludge which is then removed easily during normal blow-down. non- toxic and non-corrosive liquid formulation and therefore can be handled easily.


RXSOL pH Boosters are dosed depending upon the feed water characteristic and alkalinity requirement. It is compatible with all other treatment chemicals. It is dosed exactly as per the dosage rate and method of RXSOL-50-5001-025
EASY TO HANDLE
pH booster is non- toxic liquid formulation and therefore can be handled easily. pH booster should be dosed continuously. Dose the dilute solution in boiler feed water line.
Key Features & Benefits:-
Minimizes corrosion of feed water tank, lines and pump
Imparts water and sludge conditioning to minimize scaling and deposition
Compatible with other treatment Chmicals
Completely biodegradable chemicals
Its antiscale property helps and Prevent from Scaling
Minimum downtime required for descaling
Multipurpose,therefore easy to use
Proper maintenance of boiler saves Power / Fuel saving upto 70%. Formation of Scale is major issue and contol of scale makes Effectively heat transfer which Increase productivity.
Hydrazine Hydrate (50 ~ 51% as N2H4);
50 ~ 51% as N2H4 solution, Chloride less than 0.1% as NaCL, For corrosion protection in boilers.
Activated Hydrazine (34 ~ 35% as N2H4).
34 ~ 35% as N2H4, Chloride less than 0.1% as NaCl, Catalyzed Hydrazine solution for corrosion Pr and related equipment.
Morpholine (C4H9NO).
Technical Grade for Boiler Water Treatment. Purity Not less than 99%.
Acid Inhibitor.
For the suppression of Hydrochloric Acid attack on Ferrous alloys, Cuprous alloys and Titanium alloys, effec up to 94°C with efficiency not less than 75% in 5% HCI solution and Acid Inhibitor concentration 2%.
Ammonia 25% (NH4OH).
25% as ammonium Hydroxide used high pressure Boiler water treatment.
It is a clear colorless liquid.
PH 11-12 @ 20 °C.
Density 0.9 g/cm3.
Chloride (CL) 0.002 mg/liter maximum.
Iron (Fe) 0.002 mg/liter maximum.
Hardness Stabilizer (POC 3000) :
Polyacrylate material of low molecular weight.
Non-volatile used for scale inhibition in sea water treatment.
The product is miscible with water in all proportions. And is clear Liquid.
PH valve 5-7.
Density @ 20°C Approx. 40%.
Chemical Characterization Sodium Polyacrylate, Modified, Aqueous solution.
Solidification temperature -20°C.
Flash point >100°C.
Ignition temperature >200°C.
Boiler Alkaline Controller